OUTPUT FILTERS AND REACTORS
Showing all 5 results
-   FN 5030 Add-on sine wave output filter module for common-mode voltage improvementRead moreFN 5030 Add-on sine wave output filter module for common-mode voltage improvement- Additional module for use with FN 5010 or FN 5020 sine wave filters only
- Reduction of common-mode interferences on motor cables
- Improvement of EMC environment
- Elimination of motor bearing damages
- Possibility to use very long unshielded motor cables
- Improvement of system reliability
 - Rated currents: 25 to 120A
- Motor power: 15 to 75kW
- Voltage: <=500VAC
- Motor frequency: 0 to 600Hz
- Switching frequency: 6 to 15kHz
- Motor cable length: <=1000m
 
-   FN 5040 / FN 5045 LC sine wave filter for motor drivesRead moreFN 5040 / FN 5045 LC sine wave filter for motor drives- Smooth sine wave without voltage peaks
- Motor protection against pulse pattern stress
- Improvement of system reliability
- Simple to install
 - Rated currents: 4.5 to 1200A
- Motor power: 1.1 to 630kW
- Frequency: dc to 400Hz
- Voltage: <=500VAC
- Motor frequency: 0 to 70Hz (200Hz)
- Switching frequency: 2 to 12kHz
- Motor cable length: <=2000m
 
-   FN 510 Output filter for motor drivesRead moreFN 510 Output filter for motor drives- Reduction of drive output voltage dv/dt
- Restriction of overvoltages on motor cables
- Reduction of motor temperature
- Increase of motor service life
- Improvement of system reliability
 - Rated currents: 4 to 66A
- Motor power: 1.5 to 30kW
- Voltage: <=520VAC
- Motor frequency: 0 to 400Hz
- Switching frequency: 2 to 16kHz
- Motor cable length: <=80m
 
-   FN 530 Sine wave and EMC output filter for motor drives with a voltage dc linkRead moreFN 530 Sine wave and EMC output filter for motor drives with a voltage dc link- Smoothing of PWM drive output voltage
- Efficient motor protection
- Reduction of common-mode interferences on motor cables
- Improvement of EMC environment
- Elimination of motor bearing damages
- Possibility to use very long unshielded motor cables
- Improvement of system reliability
 - Rated currents: 4 to 16A
- Motor power: 1.5 to 7.5kW
- Voltage: <=520VAC
- Motor frequency: 0 to 200Hz
- Switching frequency: 6 to 20kHz
- Motor cable length: <=1000m
 
-   RWK 305 Three-phase dv/dt reactor for efficient motor protectionRead moreRWK 305 Three-phase dv/dt reactor for efficient motor protection- Reduction of drive output voltage dv/dt
- Reduction of motor temperature
- Increase of motor service life
- Compact and economic open frame design
- Standard catalog reactors
- UL rated materials used
 - Rated currents: 4 to 1100A
- Motor power: 1.5 to 630kW
- Voltage: <=500VAC
- Motor frequency: 0 to 60Hz
- Switching frequency: 2 to 16kHz
- Motor cable length: <=30m
 